Total
307321 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2025-7849 | 1 Ni | 1 Labview | 2025-08-19 | 7.8 High |
A memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions. | ||||
CVE-2025-51501 | 1 Microweber | 1 Microweber | 2025-08-19 | 6.1 Medium |
Reflected Cross-Site Scripting (XSS) in the id parameter of the live_edit.module_settings API endpoint in Microweber CMS2.0 allows execution of arbitrary JavaScript. | ||||
CVE-2025-51502 | 1 Microweber | 2 Cms, Microweber | 2025-08-19 | 6.1 Medium |
Reflected Cross-Site Scripting (XSS) in Microweber CMS 2.0 via the layout parameter on the /admin/page/create page allows arbitrary JavaScript execution in the context of authenticated admin users. | ||||
CVE-2025-51504 | 1 Microweber | 2 Cms, Microweber | 2025-08-19 | 7.6 High |
Microweber CMS 2.0 is vulnerable to Cross Site Scripting (XSS)in the /projects/profile, homepage endpoint via the last name field. | ||||
CVE-2025-32829 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32830 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32831 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32832 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32833 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32834 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariablesWithImport' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32835 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariableArchivingBuffering' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32836 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32837 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32838 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32839 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetGateways' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32840 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32841 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32842 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetUsers' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32843 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2024-42472 | 3 Debian, Flatpak, Redhat | 8 Debian Linux, Flatpak, Enterprise Linux and 5 more | 2025-08-19 | 10 Critical |
Flatpak is a Linux application sandboxing and distribution framework. Prior to versions 1.14.0 and 1.15.10, a malicious or compromised Flatpak app using persistent directories could access and write files outside of what it would otherwise have access to, which is an attack on integrity and confidentiality. When `persistent=subdir` is used in the application permissions (represented as `--persist=subdir` in the command-line interface), that means that an application which otherwise doesn't have access to the real user home directory will see an empty home directory with a writeable subdirectory `subdir`. Behind the scenes, this directory is actually a bind mount and the data is stored in the per-application directory as `~/.var/app/$APPID/subdir`. This allows existing apps that are not aware of the per-application directory to still work as intended without general home directory access. However, the application does have write access to the application directory `~/.var/app/$APPID` where this directory is stored. If the source directory for the `persistent`/`--persist` option is replaced by a symlink, then the next time the application is started, the bind mount will follow the symlink and mount whatever it points to into the sandbox. Partial protection against this vulnerability can be provided by patching Flatpak using the patches in commits ceec2ffc and 98f79773. However, this leaves a race condition that could be exploited by two instances of a malicious app running in parallel. Closing the race condition requires updating or patching the version of bubblewrap that is used by Flatpak to add the new `--bind-fd` option using the patch and then patching Flatpak to use it. If Flatpak has been configured at build-time with `-Dsystem_bubblewrap=bwrap` (1.15.x) or `--with-system-bubblewrap=bwrap` (1.14.x or older), or a similar option, then the version of bubblewrap that needs to be patched is a system copy that is distributed separately, typically `/usr/bin/bwrap`. This configuration is the one that is typically used in Linux distributions. If Flatpak has been configured at build-time with `-Dsystem_bubblewrap=` (1.15.x) or with `--without-system-bubblewrap` (1.14.x or older), then it is the bundled version of bubblewrap that is included with Flatpak that must be patched. This is typically installed as `/usr/libexec/flatpak-bwrap`. This configuration is the default when building from source code. For the 1.14.x stable branch, these changes are included in Flatpak 1.14.10. The bundled version of bubblewrap included in this release has been updated to 0.6.3. For the 1.15.x development branch, these changes are included in Flatpak 1.15.10. The bundled version of bubblewrap in this release is a Meson "wrap" subproject, which has been updated to 0.10.0. The 1.12.x and 1.10.x branches will not be updated for this vulnerability. Long-term support OS distributions should backport the individual changes into their versions of Flatpak and bubblewrap, or update to newer versions if their stability policy allows it. As a workaround, avoid using applications using the `persistent` (`--persist`) permission. |