CVE-2025-32829 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32830 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32831 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32832 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32833 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32834 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariablesWithImport' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32835 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariableArchivingBuffering' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32836 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32837 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32838 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32839 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetGateways' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32840 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32841 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGateway' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32842 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetUsers' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2025-32843 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | ||||
CVE-2024-42472 | 3 Debian, Flatpak, Redhat | 8 Debian Linux, Flatpak, Enterprise Linux and 5 more | 2025-08-19 | 10 Critical |
Flatpak is a Linux application sandboxing and distribution framework. Prior to versions 1.14.0 and 1.15.10, a malicious or compromised Flatpak app using persistent directories could access and write files outside of what it would otherwise have access to, which is an attack on integrity and confidentiality. When `persistent=subdir` is used in the application permissions (represented as `--persist=subdir` in the command-line interface), that means that an application which otherwise doesn't have access to the real user home directory will see an empty home directory with a writeable subdirectory `subdir`. Behind the scenes, this directory is actually a bind mount and the data is stored in the per-application directory as `~/.var/app/$APPID/subdir`. This allows existing apps that are not aware of the per-application directory to still work as intended without general home directory access. However, the application does have write access to the application directory `~/.var/app/$APPID` where this directory is stored. If the source directory for the `persistent`/`--persist` option is replaced by a symlink, then the next time the application is started, the bind mount will follow the symlink and mount whatever it points to into the sandbox. Partial protection against this vulnerability can be provided by patching Flatpak using the patches in commits ceec2ffc and 98f79773. However, this leaves a race condition that could be exploited by two instances of a malicious app running in parallel. Closing the race condition requires updating or patching the version of bubblewrap that is used by Flatpak to add the new `--bind-fd` option using the patch and then patching Flatpak to use it. If Flatpak has been configured at build-time with `-Dsystem_bubblewrap=bwrap` (1.15.x) or `--with-system-bubblewrap=bwrap` (1.14.x or older), or a similar option, then the version of bubblewrap that needs to be patched is a system copy that is distributed separately, typically `/usr/bin/bwrap`. This configuration is the one that is typically used in Linux distributions. If Flatpak has been configured at build-time with `-Dsystem_bubblewrap=` (1.15.x) or with `--without-system-bubblewrap` (1.14.x or older), then it is the bundled version of bubblewrap that is included with Flatpak that must be patched. This is typically installed as `/usr/libexec/flatpak-bwrap`. This configuration is the default when building from source code. For the 1.14.x stable branch, these changes are included in Flatpak 1.14.10. The bundled version of bubblewrap included in this release has been updated to 0.6.3. For the 1.15.x development branch, these changes are included in Flatpak 1.15.10. The bundled version of bubblewrap in this release is a Meson "wrap" subproject, which has been updated to 0.10.0. The 1.12.x and 1.10.x branches will not be updated for this vulnerability. Long-term support OS distributions should backport the individual changes into their versions of Flatpak and bubblewrap, or update to newer versions if their stability policy allows it. As a workaround, avoid using applications using the `persistent` (`--persist`) permission. | ||||
CVE-2024-25633 | 1 Elabftw | 1 Elabftw | 2025-08-19 | 5.4 Medium |
eLabFTW is an open source electronic lab notebook for research labs. In an eLabFTW system, one can configure who is allowed to create new user accounts. A vulnerability has been found starting in version 4.4.0 and prior to version 5.0.0 that allows regular users to create new, validated accounts in their team. If the system has anonymous access enabled (disabled by default) an unauthenticated user can create regular users in any team. This vulnerability has been fixed since version 5.0.0, released on February 17th 2024. Some workarounds are available. Disabling both options that allow *administrators* to create users will provide a mitigation. Additionally, disabling anonymous user access will stop anonymous access (including using existing access keys). | ||||
CVE-2025-1432 | 1 Autodesk | 9 Advance Steel, Autocad, Autocad Architecture and 6 more | 2025-08-19 | 7.8 High |
A maliciously crafted 3DM file, when parsed through Autodesk AutoCAD, can force a Use-After-Free vulnerability. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process. | ||||
CVE-2024-11216 | 2025-08-19 | 7.6 High | ||
Authorization Bypass Through User-Controlled Key, Exposure of Private Personal Information to an Unauthorized Actor vulnerability in PozitifIK Pik Online allows Account Footprinting, Session Hijacking.This issue affects Pik Online: before 3.1.5. | ||||
CVE-2025-32844 | 1 Siemens | 1 Telecontrol Server Basic | 2025-08-19 | 8.8 High |
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockUser' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. |