Filtered by vendor Siemens
Subscriptions
Total
2197 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-40936 | 1 Siemens | 1 Ps Iges Parasolid Translator Component | 2025-11-18 | 7.8 High |
| A vulnerability has been identified in PS/IGES Parasolid Translator Component (All versions < V29.0.258). The affected applications contains an out of bounds read vulnerability while parsing specially crafted IGS files. This could allow an attacker to crash the application or execute code in the context of the current process. (ZDI-CAN-26755) | ||||
| CVE-2025-40834 | 2 Mendix, Siemens | 2 Mendix, Mendix | 2025-11-18 | 5.7 Medium |
| A vulnerability has been identified in Mendix RichText (All versions >= V4.0.0 < V4.6.1). Affected widget does not properly neutralize the input. This could allow an attacker to execute cross-site scripting attacks. | ||||
| CVE-2025-40817 | 1 Siemens | 2 Logo!, Siplus Logo! | 2025-11-12 | 6.5 Medium |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently. | ||||
| CVE-2024-32008 | 1 Siemens | 1 Spectrum Power 4 | 2025-11-12 | 7.8 High |
| A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to an exposed debug interface on the localhost. This allows any local user to gain code execution as administrative application user. | ||||
| CVE-2024-32009 | 1 Siemens | 1 Spectrum Power 4 | 2025-11-12 | 7.8 High |
| A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to wrongly set permissions to a binary which allows any local attacker to gain administrative privileges. | ||||
| CVE-2024-32010 | 1 Siemens | 1 Spectrum Power 4 | 2025-11-12 | 7.8 High |
| A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to extraction of database credentials via a world-readable credential file. This allows an attacker to connect to the database as privileged application user and to run system commands via the database. | ||||
| CVE-2024-32011 | 1 Siemens | 1 Spectrum Power 4 | 2025-11-12 | 8.8 High |
| A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to run arbitrary commands via the user interface. This user interface can be used via the network and allows the execution of commands as administrative application user. | ||||
| CVE-2024-32014 | 1 Siemens | 1 Spectrum Power 4 | 2025-11-12 | 4.7 Medium |
| A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to alter the local database which contains the application credentials. This allows an attacker to gain administrative application privileges. | ||||
| CVE-2025-40744 | 1 Siemens | 1 Solid Edge Se2025 | 2025-11-12 | 7.5 High |
| A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 11). Affected applications do not properly validate client certificates to connect to License Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks. | ||||
| CVE-2025-40760 | 1 Siemens | 1 Altair Grid Engine | 2025-11-12 | 5.5 Medium |
| A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly handle error messages and discloses sensitive password hash information when processing user authentication requests. This could allow a local attacker to extract password hashes for privileged accounts, which can then be subjected to offline brute-force attacks. | ||||
| CVE-2025-40763 | 1 Siemens | 1 Altair Grid Engine | 2025-11-12 | 7.8 High |
| A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly validate environment variables when loading shared libraries, allowing path hijacking through malicious library substitution. This could allow a local attacker to execute arbitrary code with superuser privileges by manipulating the environment variable and placing a malicious library in the controlled path. | ||||
| CVE-2025-40815 | 1 Siemens | 2 Logo!, Siplus Logo! | 2025-11-12 | 7.2 High |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code. | ||||
| CVE-2025-40827 | 1 Siemens | 2 Software Center, Solid Edge Se2025 | 2025-11-12 | 7.8 High |
| A vulnerability has been identified in Siemens Software Center (All versions < V3.5), Solid Edge SE2025 (All versions < V225.0 Update 10). The affected application is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system. | ||||
| CVE-2025-40816 | 1 Siemens | 2 Logo!, Siplus Logo! | 2025-11-12 | 7.6 High |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. | ||||
| CVE-2022-34464 | 1 Siemens | 4 Sicam Gridedge Essential Arm, Sicam Gridedge Essential Gds Arm, Sicam Gridedge Essential Gds Intel and 1 more | 2025-11-12 | 6.3 Medium |
| A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.7.3). The affected application uses an improperly protected file to import SSH keys. This could allow attackers with access to the filesystem of the host on which SICAM GridEdge runs to inject a custom SSH key to that file. | ||||
| CVE-2022-30231 | 1 Siemens | 1 Sicam Gridedge Essential | 2025-11-12 | 4.9 Medium |
| A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application discloses password hashes of other users upon request. This could allow an authenticated user to retrieve another user's password hash. | ||||
| CVE-2022-30230 | 1 Siemens | 1 Sicam Gridedge Essential | 2025-11-12 | 9.8 Critical |
| A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions. | ||||
| CVE-2022-30229 | 1 Siemens | 1 Sicam Gridedge Essential | 2025-11-12 | 7.2 High |
| A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of a user, such as credentials, in case that user's id is known. | ||||
| CVE-2022-30228 | 1 Siemens | 1 Sicam Gridedge Essential | 2025-11-12 | 8.8 High |
| A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected software does not apply cross-origin resource sharing (CORS) restrictions for critical operations. In case an attacker tricks a legitimate user into accessing a special resource a malicious request could be executed. | ||||
| CVE-2023-31238 | 1 Siemens | 2 Q200, Q200 Firmware | 2025-11-11 | 5.5 Medium |
| A vulnerability has been identified in SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA00-2AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA10-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA10-2AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA30-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA30-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA01-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA01-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA02-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA02-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA11-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA11-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA12-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA12-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA31-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA31-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA32-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA32-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA00-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA00-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA10-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA10-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA30-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA30-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA01-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA01-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA02-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA02-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA11-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA11-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA12-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA12-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA31-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA31-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA32-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA32-2AA0) (All versions < V3.11). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user. | ||||