Total
13394 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2021-22789 | 1 Schneider-electric | 49 Modicon M340 Bmxp341000, Modicon M340 Bmxp342010, Modicon M340 Bmxp342020 and 46 more | 2024-11-21 | 6.5 Medium |
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions). | ||||
CVE-2021-22761 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition. | ||||
CVE-2021-22714 | 1 Schneider-electric | 6 Powerlogic Ion7400, Powerlogic Ion7400 Firmware, Powerlogic Ion9000 and 3 more | 2024-11-21 | 9.8 Critical |
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution. | ||||
CVE-2021-22713 | 1 Schneider-electric | 21 Ion7650 Firmware, Powerlogic Ion7300, Powerlogic Ion7300 Firmware and 18 more | 2024-11-21 | 7.5 High |
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot. | ||||
CVE-2021-22712 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address. | ||||
CVE-2021-22711 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to missing validation of input data. | ||||
CVE-2021-22710 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2021-22709 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. | ||||
CVE-2021-22705 | 1 Schneider-electric | 9 Ecostruxure Machine Expert, Harmony Gk, Harmony Gto and 6 more | 2024-11-21 | 7.8 High |
Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert | ||||
CVE-2021-22649 | 2 Luxion, Siemens | 8 Keyshot, Keyshot Network Rendering, Keyshot Viewer and 5 more | 2024-11-21 | 7.8 High |
Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 have multiple NULL pointer dereference issues while processing project files, which may allow an attacker to execute arbitrary code. | ||||
CVE-2021-22543 | 5 Debian, Fedoraproject, Linux and 2 more | 29 Debian Linux, Fedora, Linux Kernel and 26 more | 2024-11-21 | 7.8 High |
An issue was discovered in Linux: KVM through Improper handling of VM_IO|VM_PFNMAP vmas in KVM can bypass RO checks and can lead to pages being freed while still accessible by the VMM and guest. This allows users with the ability to start and control a VM to read/write random pages of memory and can result in local privilege escalation. | ||||
CVE-2021-22479 | 1 Huawei | 1 Harmonyos | 2024-11-21 | 5.5 Medium |
The interface of a certain HarmonyOS module has an invalid address access vulnerability. Successful exploitation of this vulnerability may lead to kernel crash. | ||||
CVE-2021-22434 | 1 Huawei | 3 Emui, Harmonyos, Magic Ui | 2024-11-21 | 9.8 Critical |
There is a memory address out of bounds vulnerability in smartphones. Successful exploitation of this vulnerability may cause malicious code to be executed. | ||||
CVE-2021-22433 | 1 Huawei | 3 Emui, Harmonyos, Magic Ui | 2024-11-21 | 9.8 Critical |
There is a memory address out of bounds in smartphones. Successful exploitation of this vulnerability may cause malicious code to be executed. | ||||
CVE-2021-22432 | 1 Huawei | 3 Emui, Harmonyos, Magic Ui | 2024-11-21 | 9.8 Critical |
There is a vulnerability when configuring permission isolation in smartphones. Successful exploitation of this vulnerability may cause out-of-bounds access. | ||||
CVE-2021-22431 | 1 Huawei | 3 Emui, Harmonyos, Magic Ui | 2024-11-21 | 9.8 Critical |
There is a vulnerability when configuring permission isolation in smartphones. Successful exploitation of this vulnerability may cause out-of-bounds access. | ||||
CVE-2021-22429 | 1 Huawei | 3 Emui, Harmonyos, Magic Ui | 2024-11-21 | 9.8 Critical |
There is a memory address out of bounds in smartphones. Successful exploitation of this vulnerability may cause malicious code to be executed. | ||||
CVE-2021-22426 | 1 Huawei | 3 Emui, Harmonyos, Magic Ui | 2024-11-21 | 9.8 Critical |
There is a memory address out of bounds in smartphones. Successful exploitation of this vulnerability may cause malicious code to be executed. | ||||
CVE-2021-21951 | 1 Anker | 2 Eufy Homebase 2, Eufy Homebase 2 Firmware | 2024-11-21 | 10.0 Critical |
An out-of-bounds write vulnerability exists in the CMD_DEVICE_GET_SERVER_LIST_REQUEST functionality of the home_security binary of Anker Eufy Homebase 2 2.1.6.9h in function read_udp_push_config_file. A specially-crafted network packet can lead to code execution. | ||||
CVE-2021-21950 | 1 Anker | 2 Eufy Homebase 2, Eufy Homebase 2 Firmware | 2024-11-21 | 10.0 Critical |
An out-of-bounds write vulnerability exists in the CMD_DEVICE_GET_SERVER_LIST_REQUEST functionality of the home_security binary of Anker Eufy Homebase 2 2.1.6.9h in function recv_server_device_response_msg_process. A specially-crafted network packet can lead to code execution. |