Total
9580 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2019-7308 | 3 Canonical, Linux, Opensuse | 3 Ubuntu Linux, Linux Kernel, Leap | 2024-11-21 | N/A |
kernel/bpf/verifier.c in the Linux kernel before 4.20.6 performs undesirable out-of-bounds speculation on pointer arithmetic in various cases, including cases of different branches with different state or limits to sanitize, leading to side-channel attacks. | ||||
CVE-2019-7305 | 3 Canonical, Debian, Extplorer | 3 Ubuntu Linux, Debian Linux, Extplorer | 2024-11-21 | 5.8 Medium |
Information Exposure vulnerability in eXtplorer makes the /usr/ and /etc/extplorer/ system directories world-accessible over HTTP. Introduced in the Makefile patch file debian/patches/debian-changes-2.1.0b6+dfsg-1 or debian/patches/adds-a-makefile.patch, this can lead to data leakage, information disclosure and potentially remote code execution on the web server. This issue affects all versions of eXtplorer in Ubuntu and Debian | ||||
CVE-2019-7259 | 1 Nortekcontrol | 4 Linear Emerge Elite, Linear Emerge Elite Firmware, Linear Emerge Essential and 1 more | 2024-11-21 | 8.8 High |
Linear eMerge E3-Series devices allow Authorization Bypass with Information Disclosure. | ||||
CVE-2019-7222 | 7 Canonical, Debian, Fedoraproject and 4 more | 19 Ubuntu Linux, Debian Linux, Fedora and 16 more | 2024-11-21 | 5.5 Medium |
The KVM implementation in the Linux kernel through 4.20.5 has an Information Leak. | ||||
CVE-2019-7005 | 1 Avaya | 1 Ip Office | 2024-11-21 | 7.5 High |
A vulnerability was discovered in the web interface component of IP Office that may potentially allow a remote, unauthenticated user with network access to gain sensitive information. Affected versions of IP Office include: 9.x, 10.0 through 10.1.0.7 and 11.0 through 11.0.4.2. | ||||
CVE-2019-6852 | 1 Schneider-electric | 20 140 Cpu6x, 140 Cpu6x Firmware, 140 Noc 77101 and 17 more | 2024-11-21 | 7.5 High |
A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network. | ||||
CVE-2019-6851 | 1 Schneider-electric | 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more | 2024-11-21 | 7.5 High |
A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol. | ||||
CVE-2019-6850 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2024-11-21 | 7.5 High |
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module. | ||||
CVE-2019-6849 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2024-11-21 | 7.5 High |
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module. | ||||
CVE-2019-6700 | 1 Fortinet | 1 Fortisiem | 2024-11-21 | 6.5 Medium |
An information exposure vulnerability in the external authentication profile form of FortiSIEM 5.2.2 and earlier may allow an authenticated attacker to retrieve the external authentication password via the HTML source code. | ||||
CVE-2019-6574 | 1 Siemens | 12 Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr2, Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr2 Firmware, Sinamics Perfect Harmony Gh180 With Nxg I Control Mlfb 6sr3 and 9 more | 2024-11-21 | 7.5 High |
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
CVE-2019-6572 | 1 Siemens | 22 Simatic Hmi Comfort Outdoor Panels, Simatic Hmi Comfort Outdoor Panels Firmware, Simatic Hmi Comfort Panels and 19 more | 2024-11-21 | 9.1 Critical |
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
CVE-2019-6331 | 1 Hp | 1 Samsung Mobile Print | 2024-11-21 | 3.3 Low |
An issue was found in Samsung Mobile Print (Android) versions prior to 4.08.007. A potential security vulnerability caused by incomplete obfuscation of application configuration information. | ||||
CVE-2019-6206 | 1 Apple | 1 Iphone Os | 2024-11-21 | N/A |
An issue existed with autofill resuming after it was canceled. The issue was addressed with improved state management. This issue is fixed in iOS 12.1.3. Password autofill may fill in passwords after they were manually cleared. | ||||
CVE-2019-6193 | 1 Lenovo | 1 Xclarity Administrator | 2024-11-21 | 7.5 High |
An information disclosure vulnerability was reported in Lenovo XClarity Administrator (LXCA) versions prior to 2.6.6 that could allow unauthenticated access to some configuration files which may contain usernames, license keys, IP addresses, and encrypted password hashes. | ||||
CVE-2019-6177 | 1 Lenovo | 1 Solution Center | 2024-11-21 | 9.8 Critical |
A vulnerability reported in Lenovo Solution Center version 03.12.003, which is no longer supported, could allow log files to be written to non-standard locations, potentially leading to privilege escalation. Lenovo ended support for Lenovo Solution Center and recommended that customers migrate to Lenovo Vantage or Lenovo Diagnostics in April 2018. | ||||
CVE-2019-5884 | 1 Std42 | 1 Elfinder | 2024-11-21 | 5.9 Medium |
php/elFinder.class.php in elFinder before 2.1.45 leaks information if PHP's curl extension is enabled and safe_mode or open_basedir is not set. | ||||
CVE-2019-5880 | 2 Google, Redhat | 2 Chrome, Rhel Extras | 2024-11-21 | 7.4 High |
Insufficient policy enforcement in Blink in Google Chrome prior to 77.0.3865.75 allowed a remote attacker to leak cross-origin data via a crafted HTML page. | ||||
CVE-2019-5640 | 1 Rapid7 | 1 Nexpose | 2024-11-21 | 3.3 Low |
Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user's session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user | ||||
CVE-2019-5601 | 1 Freebsd | 1 Freebsd | 2024-11-21 | N/A |
In FreeBSD 12.0-STABLE before r347474, 12.0-RELEASE before 12.0-RELEASE-p7, 11.2-STABLE before r347475, and 11.2-RELEASE before 11.2-RELEASE-p11, a bug in the FFS implementation causes up to three bytes of kernel stack memory to be written to disk as uninitialized directory entry padding. |