Total
1196 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2021-28499 | 1 Arista | 2 7130, Metamako Operating System | 2024-11-21 | 6.3 Medium |
In Arista's MOS (Metamako Operating System) software which is supported on the 7130 product line, user account passwords set in clear text could leak to users without any password. This issue affects: Arista Metamako Operating System MOS-0.18 and post releases in the MOS-0.1x train All releases in the MOS-0.2x train MOS-0.31.1 and prior releases in the MOS-0.3x train | ||||
CVE-2021-28498 | 1 Arista | 2 7130, Metamako Operating System | 2024-11-21 | 8.7 High |
In Arista's MOS (Metamako Operating System) software which is supported on the 7130 product line, user enable passwords set in clear text could result in unprivileged users getting complete access to the systems. This issue affects: Arista Metamako Operating System MOS-0.13 and post releases in the MOS-0.1x train MOS-0.26.6 and prior releases in the MOS-0.2x train MOS-0.31.1 and prior releases in the MOS-0.3x train | ||||
CVE-2021-28496 | 1 Arista | 1 Eos | 2024-11-21 | 5.7 Medium |
On systems running Arista EOS and CloudEOS with the affected release version, when using shared secret profiles the password configured for use by BiDirectional Forwarding Detection (BFD) will be leaked when displaying output over eAPI or other JSON outputs to other authenticated users on the device. The affected EOS Versions are: all releases in 4.22.x train, 4.23.9 and below releases in the 4.23.x train, 4.24.7 and below releases in the 4.24.x train, 4.25.4 and below releases in the 4.25.x train, 4.26.1 and below releases in the 4.26.x train | ||||
CVE-2021-28171 | 1 Deltaflow Project | 1 Deltaflow | 2024-11-21 | 9.8 Critical |
The Vangene deltaFlow E-platform does not take properly protective measures. Attackers can obtain privileged permissions remotely by tampering with users’ data in the Cookie. | ||||
CVE-2021-27941 | 1 Coolkit | 1 Ewelink | 2024-11-21 | 4.6 Medium |
Unconstrained Web access to the device's private encryption key in the QR code pairing mode in the eWeLink mobile application (through 4.9.2 on Android and through 4.9.1 on iOS) allows a physically proximate attacker to eavesdrop on Wi-Fi credentials and other sensitive information by monitoring the Wi-Fi spectrum during a device pairing process. | ||||
CVE-2021-27935 | 1 Adguard | 1 Adguard Home | 2024-11-21 | 7.5 High |
An issue was discovered in AdGuard before 0.105.2. An attacker able to get the user's cookie is able to bruteforce their password offline, because the hash of the password is stored in the cookie. | ||||
CVE-2021-27785 | 1 Hcltechsw | 1 Hcl Commerce | 2024-11-21 | 3.9 Low |
HCL Commerce's Remote Store server could allow a local attacker to obtain sensitive personal information. The vulnerability requires the victim to first perform a particular operation on the website. | ||||
CVE-2021-27495 | 1 Ypsomed | 2 Mylife, Mylife Cloud | 2024-11-21 | 7.1 High |
Ypsomed mylife Cloud, mylife Mobile Application:Ypsomed mylife Cloud,All versions prior to 1.7.2,Ypsomed mylife App,All versions prior to 1.7.5,he Ypsomed mylife Cloud reflects the user password during the login process after redirecting the user from a HTTPS endpoint to a HTTP endpoint. | ||||
CVE-2021-27491 | 1 Ypsomed | 2 Mylife, Mylife Cloud | 2024-11-21 | 7.5 High |
Ypsomed mylife Cloud, mylife Mobile Application:Ypsomed mylife Cloud,All versions prior to 1.7.2,Ypsomed mylife App,All versions prior to 1.7.5,The Ypsomed mylife Cloud discloses password hashes during the registration process. | ||||
CVE-2021-27372 | 1 Realtek | 2 Xpon Rtl9601d, Xpon Rtl9601d Software Development Kit | 2024-11-21 | 9.8 Critical |
Realtek xPON RTL9601D SDK 1.9 stores passwords in plaintext which may allow attackers to possibly gain access to the device with root permissions via the build-in network monitoring tool and execute arbitrary commands. | ||||
CVE-2021-27187 | 1 Xn--b1agzlht | 1 Fx Aggregator Terminal Client | 2024-11-21 | 7.5 High |
The Sovremennye Delovye Tekhnologii FX Aggregator terminal client 1 stores authentication credentials in cleartext in login.sav when the Save Password box is checked. | ||||
CVE-2021-25742 | 2 Kubernetes, Netapp | 2 Ingress-nginx, Trident | 2024-11-21 | 7.6 High |
A security issue was discovered in ingress-nginx where a user that can create or update ingress objects can use the custom snippets feature to obtain all secrets in the cluster. | ||||
CVE-2021-25284 | 3 Debian, Fedoraproject, Saltstack | 3 Debian Linux, Fedora, Salt | 2024-11-21 | 4.4 Medium |
An issue was discovered in through SaltStack Salt before 3002.5. salt.modules.cmdmod can log credentials to the info or error log level. | ||||
CVE-2021-23222 | 2 Postgresql, Redhat | 3 Postgresql, Enterprise Linux, Rhel Software Collections | 2024-11-21 | 5.9 Medium |
A man-in-the-middle attacker can inject false responses to the client's first few queries, despite the use of SSL certificate verification and encryption. | ||||
CVE-2021-23019 | 1 F5 | 1 Nginx Controller | 2024-11-21 | 7.8 High |
The NGINX Controller 2.0.0 thru 2.9.0 and 3.x before 3.15.0 Administrator password may be exposed in the systemd.txt file that is included in the NGINX support package. | ||||
CVE-2021-22923 | 7 Fedoraproject, Haxx, Netapp and 4 more | 25 Fedora, Curl, Cloud Backup and 22 more | 2024-11-21 | 5.3 Medium |
When curl is instructed to get content using the metalink feature, and a user name and password are used to download the metalink XML file, those same credentials are then subsequently passed on to each of the servers from which curl will download or try to download the contents from. Often contrary to the user's expectations and intentions and without telling the user it happened. | ||||
CVE-2021-22798 | 1 Schneider-electric | 2 Conext Combox, Conext Combox Firmware | 2024-11-21 | 7.5 High |
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions) | ||||
CVE-2021-22781 | 1 Schneider-electric | 3 Ecostruxure Control Expert, Ecostruxure Process Expert, Remoteconnect | 2024-11-21 | 5.5 Medium |
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file. | ||||
CVE-2021-22780 | 1 Schneider-electric | 3 Ecostruxure Control Expert, Ecostruxure Process Expert, Remoteconnect | 2024-11-21 | 7.1 High |
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file. | ||||
CVE-2021-22778 | 1 Schneider-electric | 3 Ecostruxure Control Expert, Ecostruxure Process Expert, Remoteconnect | 2024-11-21 | 7.1 High |
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file. |