Filtered by vendor Siemens
Subscriptions
Total
2170 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-45937 | 1 Siemens | 18 Pxc00-e96.a, Pxc00-e96.a Firmware, Pxc100-e96.a and 15 more | 2025-04-21 | 8.8 High |
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). A low privilege authenticated attacker with network access to the integrated web server could download sensitive information from the device containing user account credentials. | ||||
CVE-2022-46140 | 1 Siemens | 202 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 199 more | 2025-04-21 | 6.5 Medium |
Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system. | ||||
CVE-2022-46142 | 1 Siemens | 202 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 199 more | 2025-04-21 | 5.7 Medium |
Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. | ||||
CVE-2022-46144 | 1 Siemens | 12 6gk5622-2gs00-2ac2, 6gk5622-2gs00-2ac2 Firmware, 6gk5626-2gs00-2ac2 and 9 more | 2025-04-21 | 6.5 Medium |
A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive. | ||||
CVE-2022-46265 | 1 Siemens | 1 Polarion Alm | 2025-04-21 | 5.4 Medium |
A vulnerability has been identified in Polarion ALM (All versions < V2304.0). The affected application contains a Host header injection vulnerability that could allow an attacker to spoof a Host header information and redirect users to malicious websites. | ||||
CVE-2022-46347 | 1 Siemens | 1 Parasolid | 2025-04-21 | 7.8 High |
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079) | ||||
CVE-2022-46348 | 1 Siemens | 1 Parasolid | 2025-04-21 | 7.8 High |
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383) | ||||
CVE-2022-46349 | 1 Siemens | 1 Parasolid | 2025-04-21 | 7.8 High |
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384) | ||||
CVE-2022-46664 | 1 Siemens | 1 Mendix Workflow Commons | 2025-04-21 | 8.1 High |
A vulnerability has been identified in Mendix Workflow Commons (All versions < V2.4.0), Mendix Workflow Commons V2.1 (All versions < V2.1.4), Mendix Workflow Commons V2.3 (All versions < V2.3.2). Affected versions of the module improperly handle access control for some module entities. This could allow authenticated remote attackers to read or delete sensitive information. | ||||
CVE-2017-12740 | 1 Siemens | 1 Logo\! Soft Comfort | 2025-04-20 | N/A |
Siemens LOGO! Soft Comfort (All versions before V8.2) lacks integrity verification of software packages downloaded via an unprotected communication channel. This could allow a remote attacker to manipulate the software package while performing a Man-in-the-Middle (MitM) attack. | ||||
CVE-2017-12739 | 1 Siemens | 2 Sm-2556, Sm-2556 Firmware | 2025-04-20 | N/A |
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected device. | ||||
CVE-2017-12738 | 1 Siemens | 2 Sm-2556, Sm-2556 Firmware | 2025-04-20 | N/A |
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link. | ||||
CVE-2015-7705 | 4 Citrix, Netapp, Ntp and 1 more | 10 Xenserver, Clustered Data Ontap, Data Ontap and 7 more | 2025-04-20 | 9.8 Critical |
The rate limiting feature in NTP 4.x before 4.2.8p4 and 4.3.x before 4.3.77 allows remote attackers to have unspecified impact via a large number of crafted requests. | ||||
CVE-2017-12735 | 1 Siemens | 2 Logo\!, Logo\! 8 Bm Firmware | 2025-04-20 | 7.4 High |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. | ||||
CVE-2017-12734 | 1 Siemens | 2 Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware | 2025-04-20 | 7.5 High |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks. | ||||
CVE-2015-5219 | 10 Canonical, Debian, Fedoraproject and 7 more | 21 Ubuntu Linux, Debian Linux, Fedora and 18 more | 2025-04-20 | 7.5 High |
The ULOGTOD function in ntp.d in SNTP before 4.2.7p366 does not properly perform type conversions from a precision value to a double, which allows remote attackers to cause a denial of service (infinite loop) via a crafted NTP packet. | ||||
CVE-2016-2518 | 7 Debian, Freebsd, Netapp and 4 more | 20 Debian Linux, Freebsd, Clustered Data Ontap and 17 more | 2025-04-20 | 5.3 Medium |
The MATCH_ASSOC function in NTP before version 4.2.8p9 and 4.3.x before 4.3.92 allows remote attackers to cause an out-of-bounds reference via an addpeer request with a large hmode value. | ||||
CVE-2017-14491 | 13 Arista, Arubanetworks, Canonical and 10 more | 35 Eos, Arubaos, Ubuntu Linux and 32 more | 2025-04-20 | 9.8 Critical |
Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response. | ||||
CVE-2017-9944 | 1 Siemens | 2 7kt Pac1200 Data Manager, 7kt Pac1200 Data Manager Firmware | 2025-04-20 | N/A |
A vulnerability has been identified in Siemens 7KT PAC1200 data manager (7KT1260) in all versions < V2.03. The integrated web server (port 80/tcp) of the affected devices could allow an unauthenticated remote attacker to perform administrative operations over the network. | ||||
CVE-2017-6873 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2025-04-20 | N/A |
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. |