Filtered by vendor Siemens Subscriptions
Total 1936 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2021-37177 1 Siemens 1 Sinema Remote Connect Server 2025-04-23 6.5 Medium
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The status provided by the syslog clients managed by the affected software can be manipulated by an unauthenticated attacker in the same network of the affected system.
CVE-2021-27391 1 Siemens 16 Apogee Mbc \(ppc\) \(p2 Ethernet\), Apogee Mbc \(ppc\) \(p2 Ethernet\) Firmware, Apogee Mec \(ppc\) \(p2 Ethernet\) and 13 more 2025-04-23 9.8 Critical
A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges.
CVE-2019-16905 3 Netapp, Openbsd, Siemens 7 Cloud Backup, Steelstore Cloud Integrated Storage, Openssh and 4 more 2025-04-23 7.8 High
OpenSSH 7.7 through 7.9 and 8.x before 8.1, when compiled with an experimental key type, has a pre-authentication integer overflow if a client or server is configured to use a crafted XMSS key. This leads to memory corruption and local code execution because of an error in the XMSS key parsing algorithm. NOTE: the XMSS implementation is considered experimental in all released OpenSSH versions, and there is no supported way to enable it when building portable OpenSSH.
CVE-2022-43724 1 Siemens 1 Sicam Pas\/pqs 2025-04-22 9.8 Critical
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0). Affected software transmits the database credentials for the inbuilt SQL server in cleartext. In combination with the by default enabled xp_cmdshell feature unauthenticated remote attackers could execute custom OS commands. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.
CVE-2022-43723 1 Siemens 1 Sicam Pas\/pqs 2025-04-22 7.5 High
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0), SICAM PAS/PQS (All versions >= 7.0 < V8.06). Affected software does not properly validate the input for a certain parameter in the s7ontcp.dll. This could allow an unauthenticated remote attacker to send messages and create a denial of service condition as the application crashes. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.
CVE-2022-43722 1 Siemens 1 Sicam Pas\/pqs 2025-04-22 7.8 High
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0). Affected software does not properly secure a folder containing library files. This could allow an attacker to place a custom malicious DLL in this folder which is then run with SYSTEM rights when a service is started that requires this DLL. At the time of assigning the CVE, the affected firmware version of the component has already been superseded by succeeding mainline versions.
CVE-2022-46355 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2025-04-22 7.5 High
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The affected products are vulnerable to an "Exposure of Sensitive Information to an Unauthorized Actor" vulnerability by leaking sensitive data in the HTTP Referer.
CVE-2022-46354 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2025-04-22 5.3 Medium
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.
CVE-2022-45936 1 Siemens 1 Mendix Email Connector 2025-04-22 8.1 High
A vulnerability has been identified in Mendix Email Connector (All versions < V2.0.0). Affected versions of the module improperly handle access control for some module entities. This could allow authenticated remote attackers to read and manipulate sensitive information.
CVE-2022-44575 1 Siemens 1 Plm Help Server 2025-04-22 6.1 Medium
A vulnerability has been identified in PLM Help Server V4.2 (All versions). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link.
CVE-2022-46353 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2025-04-22 9.8 Critical
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.
CVE-2022-46352 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2025-04-22 7.5 High
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). Specially crafted PROFINET DCP packets could cause a denial of service condition of affected products.
CVE-2022-46351 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2025-04-22 5.5 Medium
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). Specially crafted PROFINET DCP packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2).
CVE-2022-46350 1 Siemens 10 6gk5204-0ba00-2kb2, 6gk5204-0ba00-2kb2 Firmware, 6gk5204-0ba00-2mb2 and 7 more 2025-04-22 6.1 Medium
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.
CVE-2021-37209 1 Siemens 54 Ruggedcom I800, Ruggedcom I801, Ruggedcom I802 and 51 more 2025-04-21 6.7 Medium
A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.8), RUGGEDCOM i801 (All versions < V4.3.8), RUGGEDCOM i802 (All versions < V4.3.8), RUGGEDCOM i803 (All versions < V4.3.8), RUGGEDCOM M2100 (All versions < V4.3.8), RUGGEDCOM M2200 (All versions < V4.3.8), RUGGEDCOM M969 (All versions < V4.3.8), RUGGEDCOM RMC30 (All versions < V4.3.8), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.8), RUGGEDCOM RMC8388 V5.X (All versions < V5.7.0), RUGGEDCOM RP110 (All versions < V4.3.8), RUGGEDCOM RS1600 (All versions < V4.3.8), RUGGEDCOM RS1600F (All versions < V4.3.8), RUGGEDCOM RS1600T (All versions < V4.3.8), RUGGEDCOM RS400 (All versions < V4.3.8), RUGGEDCOM RS401 (All versions < V4.3.8), RUGGEDCOM RS416 (All versions < V4.3.8), RUGGEDCOM RS416P (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.7.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416v2 V5.X (All versions < V5.7.0), RUGGEDCOM RS8000 (All versions < V4.3.8), RUGGEDCOM RS8000A (All versions < V4.3.8), RUGGEDCOM RS8000H (All versions < V4.3.8), RUGGEDCOM RS8000T (All versions < V4.3.8), RUGGEDCOM RS900 (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900G (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900GP (All versions < V4.3.8), RUGGEDCOM RS900L (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-XX (All versions < V4.3.8), RUGGEDCOM RS900M-STND-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-STND-XX (All versions < V4.3.8), RUGGEDCOM RS900W (All versions < V4.3.8), RUGGEDCOM RS910 (All versions < V4.3.8), RUGGEDCOM RS910L (All versions < V4.3.8), RUGGEDCOM RS910W (All versions < V4.3.8), RUGGEDCOM RS920L (All versions < V4.3.8), RUGGEDCOM RS920W (All versions < V4.3.8), RUGGEDCOM RS930L (All versions < V4.3.8), RUGGEDCOM RS930W (All versions < V4.3.8), RUGGEDCOM RS940G (All versions < V4.3.8), RUGGEDCOM RS969 (All versions < V4.3.8), RUGGEDCOM RSG2100 (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2100P (All versions < V4.3.8), RUGGEDCOM RSG2200 (All versions < V4.3.8), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2288 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300P V5.X (All versions < V5.7.0), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2488 V5.X (All versions < V5.7.0), RUGGEDCOM RSG907R (All versions < V5.7.0), RUGGEDCOM RSG908C (All versions < V5.7.0), RUGGEDCOM RSG909R (All versions < V5.7.0), RUGGEDCOM RSG910C (All versions < V5.7.0), RUGGEDCOM RSG920P V4.X (All versions < V4.3.8), RUGGEDCOM RSG920P V5.X (All versions < V5.7.0), RUGGEDCOM RSL910 (All versions < V5.7.0), RUGGEDCOM RST2228 (All versions < V5.7.0), RUGGEDCOM RST2228P (All versions < V5.7.0), RUGGEDCOM RST916C (All versions < V5.7.0), RUGGEDCOM RST916P (All versions < V5.7.0). The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device.
CVE-2022-24281 1 Siemens 1 Sinec Network Management System 2025-04-21 7.2 High
A vulnerability has been identified in SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). A privileged authenticated attacker could execute arbitrary commands in the local database by sending specially crafted requests to the webserver of the affected application.
CVE-2022-24282 1 Siemens 1 Sinec Network Management System 2025-04-21 7.2 High
A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected system allows to upload JSON objects that are deserialized to Java objects. Due to insecure deserialization of user-supplied content by the affected software, a privileged attacker could exploit this vulnerability by sending a maliciously crafted serialized Java object. This could allow the attacker to execute arbitrary code on the device with root privileges.
CVE-2022-25311 1 Siemens 2 Sinec Network Management System, Sinema Server 2025-04-21 7.3 High
A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected software do not properly check privileges between users during the same web browser session, creating an unintended sphere of control. This could allow an authenticated low privileged user to achieve privilege escalation.
CVE-2022-25622 1 Siemens 23 Simatic Cfu Diq, Simatic Cfu Diq Firmware, Simatic Cfu Pa and 20 more 2025-04-21 5.3 Medium
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
CVE-2021-40368 1 Siemens 8 Simatic S7-400 Pn\/dp V7, Simatic S7-400 Pn\/dp V7 Firmware, Simatic S7-400h V6 and 5 more 2025-04-21 7.5 High
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.10), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions < V10.1), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions < V8.2.3), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a Denial-of-Service condition. A restart is needed to restore normal operations.