Total
1347 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-21599 | 1 Juniper | 1 Junos | 2025-06-16 | 6.5 Medium |
| A Missing Release of Memory after Effective Lifetime vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on MX Series allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS). If an MX Series device receives PTP packets on an MPC3E that doesn't support PTP this causes a memory leak which will result in unpredictable behavior and ultimately in an MPC crash and restart. To monitor for this issue, please use the following FPC vty level commands: show heap shows an increase in "LAN buffer" utilization and show clksync ptp nbr-upd-info shows non-zero "Pending PFEs" counter. This issue affects Juniper Networks Junos OS on MX Series with MPC3E: * All versions earlier than 20.4R3-S3; * 21.1 versions earlier than 21.1R3-S4; * 21.2 versions earlier than 21.2R3; * 21.3 versions earlier than 21.3R2-S1, 21.3R3; * 21.4 versions earlier than 21.4R2; * 22.1 versions earlier than 22.1R2. | ||||
| CVE-2019-20386 | 6 Canonical, Fedoraproject, Netapp and 3 more | 9 Ubuntu Linux, Fedora, Active Iq Unified Manager and 6 more | 2025-06-09 | 5.1 Medium |
| An issue was discovered in button_open in login/logind-button.c in systemd before 243. When executing the udevadm trigger command, a memory leak may occur. | ||||
| CVE-2022-23091 | 1 Freebsd | 1 Freebsd | 2025-06-04 | 4 Medium |
| A particular case of memory sharing is mishandled in the virtual memory system. This is very similar to SA-21:08.vm, but with a different root cause. An unprivileged local user process can maintain a mapping of a page after it is freed, allowing that process to read private data belonging to other processes or the kernel. | ||||
| CVE-2024-22563 | 1 Openvswitch | 1 Openvswitch | 2025-06-02 | 7.5 High |
| openvswitch 2.17.8 was discovered to contain a memory leak via the function xmalloc__ in openvswitch-2.17.8/lib/util.c. | ||||
| CVE-2022-38178 | 5 Debian, Fedoraproject, Isc and 2 more | 8 Debian Linux, Fedora, Bind and 5 more | 2025-05-28 | 7.5 High |
| By spoofing the target resolver with responses that have a malformed EdDSA signature, an attacker can trigger a small memory leak. It is possible to gradually erode available memory to the point where named crashes for lack of resources. | ||||
| CVE-2022-38177 | 5 Debian, Fedoraproject, Isc and 2 more | 8 Debian Linux, Fedora, Bind and 5 more | 2025-05-28 | 7.5 High |
| By spoofing the target resolver with responses that have a malformed ECDSA signature, an attacker can trigger a small memory leak. It is possible to gradually erode available memory to the point where named crashes for lack of resources. | ||||
| CVE-2022-2906 | 1 Isc | 1 Bind | 2025-05-28 | 7.5 High |
| An attacker can leverage this flaw to gradually erode available memory to the point where named crashes for lack of resources. Upon restart the attacker would have to begin again, but nevertheless there is the potential to deny service. | ||||
| CVE-2025-23165 | 1 Redhat | 1 Enterprise Linux | 2025-05-28 | N/A |
| In Node.js, the `ReadFileUtf8` internal binding leaks memory due to a corrupted pointer in `uv_fs_s.file`: a UTF-16 path buffer is allocated but subsequently overwritten when the file descriptor is set. This results in an unrecoverable memory leak on every call. Repeated use can cause unbounded memory growth, leading to a denial of service. Impact: * This vulnerability affects APIs relying on `ReadFileUtf8` on Node.js release lines: v20 and v22. | ||||
| CVE-2025-47935 | 2025-05-27 | 7.5 High | ||
| Multer is a node.js middleware for handling `multipart/form-data`. Versions prior to 2.0.0 are vulnerable to a resource exhaustion and memory leak issue due to improper stream handling. When the HTTP request stream emits an error, the internal `busboy` stream is not closed, violating Node.js stream safety guidance. This leads to unclosed streams accumulating over time, consuming memory and file descriptors. Under sustained or repeated failure conditions, this can result in denial of service, requiring manual server restarts to recover. All users of Multer handling file uploads are potentially impacted. Users should upgrade to 2.0.0 to receive a patch. No known workarounds are available. | ||||
| CVE-2022-35085 | 1 Swftools | 1 Swftools | 2025-05-27 | 5.5 Medium |
| SWFTools commit 772e55a2 was discovered to contain a memory leak via /lib/mem.c. | ||||
| CVE-2024-27508 | 1 Atheme | 1 Atheme | 2025-05-23 | 7.5 High |
| Atheme 7.2.12 contains a memory leak vulnerability in /atheme/src/crypto-benchmark/main.c. | ||||
| CVE-2024-26458 | 3 Mit, Netapp, Redhat | 13 Kerberos 5, Active Iq Unified Manager, Cloud Volumes Ontap Mediator and 10 more | 2025-05-23 | 5.3 Medium |
| Kerberos 5 (aka krb5) 1.21.2 contains a memory leak in /krb5/src/lib/rpc/pmap_rmt.c. | ||||
| CVE-2024-26461 | 3 Mit, Netapp, Redhat | 13 Kerberos 5, Active Iq Unified Manager, Cloud Volumes Ontap Mediator and 10 more | 2025-05-23 | 7.5 High |
| Kerberos 5 (aka krb5) 1.21.2 contains a memory leak vulnerability in /krb5/src/lib/gssapi/krb5/k5sealv3.c. | ||||
| CVE-2024-35930 | 3 Debian, Linux, Redhat | 4 Debian Linux, Linux Kernel, Enterprise Linux and 1 more | 2025-05-21 | 5.5 Medium |
| In the Linux kernel, the following vulnerability has been resolved: scsi: lpfc: Fix possible memory leak in lpfc_rcv_padisc() The call to lpfc_sli4_resume_rpi() in lpfc_rcv_padisc() may return an unsuccessful status. In such cases, the elsiocb is not issued, the completion is not called, and thus the elsiocb resource is leaked. Check return value after calling lpfc_sli4_resume_rpi() and conditionally release the elsiocb resource. | ||||
| CVE-2022-48698 | 1 Linux | 1 Linux Kernel | 2025-05-21 | 5.3 Medium |
| In the Linux kernel, the following vulnerability has been resolved: drm/amd/display: fix memory leak when using debugfs_lookup() When calling debugfs_lookup() the result must have dput() called on it, otherwise the memory will leak over time. Fix this up by properly calling dput(). | ||||
| CVE-2021-47550 | 1 Linux | 1 Linux Kernel | 2025-05-21 | 5.5 Medium |
| In the Linux kernel, the following vulnerability has been resolved: drm/amd/amdgpu: fix potential memleak In function amdgpu_get_xgmi_hive, when kobject_init_and_add failed There is a potential memleak if not call kobject_put. | ||||
| CVE-2022-41847 | 1 Axiosys | 1 Bento4 | 2025-05-20 | 5.5 Medium |
| An issue was discovered in Bento4 1.6.0-639. A memory leak exists in AP4_StdcFileByteStream::Create(AP4_FileByteStream*, char const*, AP4_FileByteStream::Mode, AP4_ByteStream*&) in System/StdC/Ap4StdCFileByteStream.cpp. | ||||
| CVE-2025-3198 | 1 Gnu | 1 Binutils | 2025-05-15 | 3.3 Low |
| A vulnerability has been found in GNU Binutils 2.43/2.44 and classified as problematic. Affected by this vulnerability is the function display_info of the file binutils/bucomm.c of the component objdump. The manipulation leads to memory leak. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. The patch is named ba6ad3a18cb26b79e0e3b84c39f707535bbc344d. It is recommended to apply a patch to fix this issue. | ||||
| CVE-2022-2963 | 3 Fedoraproject, Jasper Project, Redhat | 3 Fedora, Jasper, Enterprise Linux | 2025-05-15 | 7.5 High |
| A vulnerability found in jasper. This security vulnerability happens because of a memory leak bug in function cmdopts_parse that can cause a crash or segmentation fault. | ||||
| CVE-2022-38371 | 1 Siemens | 39 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 36 more | 2025-05-13 | 7.5 High |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), Desigo PXC00-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC00-U (All versions >= V2.3 < V6.30.37), Desigo PXC001-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC100-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC12-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC128-U (All versions >= V2.3 < V6.30.37), Desigo PXC200-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC50-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC64-U (All versions >= V2.3 < V6.30.37), Desigo PXM20-E (All versions >= V2.3 < V6.30.37), Nucleus NET for Nucleus PLUS V1 (All versions < V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions < V5.4), Nucleus ReadyStart V3 V2012 (All versions < V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions < V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server. | ||||