Filtered by CWE-284
Total 3871 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2019-12648 1 Cisco 6 807 Industrial Integrated Services Routers, 809 Industrial Integrated Services Routers, 829 Industrial Integrated Services Routers and 3 more 2024-11-21 8.8 High
A vulnerability in the IOx application environment for Cisco IOS Software could allow an authenticated, remote attacker to gain unauthorized access to the Guest Operating System (Guest OS) running on an affected device. The vulnerability is due to incorrect role-based access control (RBAC) evaluation when a low-privileged user requests access to a Guest OS that should be restricted to administrative accounts. An attacker could exploit this vulnerability by authenticating to the Guest OS by using the low-privileged-user credentials. An exploit could allow the attacker to gain unauthorized access to the Guest OS as a root user.
CVE-2019-12627 1 Cisco 29 Amp 7150, Amp 8150, Firepower 7010 and 26 more 2024-11-21 7.5 High
A vulnerability in the application policy configuration of the Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to gain unauthorized read access to sensitive data. The vulnerability is due to insufficient application identification. An attacker could exploit this vulnerability by sending crafted traffic to an affected device. A successful exploit could allow the attacker to gain unauthorized read access to sensitive data.
CVE-2019-12418 7 Apache, Canonical, Debian and 4 more 7 Tomcat, Ubuntu Linux, Debian Linux and 4 more 2024-11-21 7.0 High
When Apache Tomcat 9.0.0.M1 to 9.0.28, 8.5.0 to 8.5.47, 7.0.0 and 7.0.97 is configured with the JMX Remote Lifecycle Listener, a local attacker without access to the Tomcat process or configuration files is able to manipulate the RMI registry to perform a man-in-the-middle attack to capture user names and passwords used to access the JMX interface. The attacker can then use these credentials to access the JMX interface and gain complete control over the Tomcat instance.
CVE-2019-11899 1 Bosch 1 Access 2024-11-21 7.5 High
An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator.
CVE-2019-11896 1 Bosch 2 Smart Home Controller, Smart Home Controller Firmware 2024-11-21 7.1 High
A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction.
CVE-2019-11895 1 Bosch 2 Smart Home Controller, Smart Home Controller Firmware 2024-11-21 5.3 Medium
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction.
CVE-2019-11894 1 Bosch 2 Smart Home Controller, Smart Home Controller Firmware 2024-11-21 5.7 Medium
A potential improper access control vulnerability exists in the backup mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in unauthorized download of a backup. In order to exploit the vulnerability, the adversary needs to download the backup directly after a backup triggered by a legitimate user has been completed.
CVE-2019-11892 1 Bosch 2 Smart Home Controller, Smart Home Controller Firmware 2024-11-21 8.0 High
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction.
CVE-2019-11786 1 Odoo 1 Odoo 2024-11-21 4.3 Medium
Improper access control in Odoo Community 13.0 and earlier and Odoo Enterprise 13.0 and earlier, allows remote authenticated users to modify translated terms, which may lead to arbitrary content modification on translatable elements.
CVE-2019-11785 1 Odoo 1 Odoo 2024-11-21 4.3 Medium
Improper access control in mail module (followers) in Odoo Community 13.0 and earlier and Odoo Enterprise 13.0 and earlier, allows remote authenticated users to obtain access to messages posted on business records there were not given access to, and subscribe to receive future messages.
CVE-2019-11784 1 Odoo 1 Odoo 2024-11-21 6.5 Medium
Improper access control in mail module (notifications) in Odoo Community 14.0 and earlier and Odoo Enterprise 14.0 and earlier, allows remote authenticated users to obtain access to arbitrary messages in conversations they were not a party to.
CVE-2019-11783 1 Odoo 1 Odoo 2024-11-21 6.5 Medium
Improper access control in mail module (channel partners) in Odoo Community 14.0 and earlier and Odoo Enterprise 14.0 and earlier, allows remote authenticated users to subscribe to arbitrary mail channels uninvited.
CVE-2019-11782 1 Odoo 1 Odoo 2024-11-21 6.5 Medium
Improper access control in Odoo Community 14.0 and earlier and Odoo Enterprise 14.0 and earlier, allows remote authenticated users with access to contact management to modify user accounts, leading to privilege escalation.
CVE-2019-11780 1 Odoo 1 Odoo 2024-11-21 8.1 High
Improper access control in the computed fields system of the framework of Odoo Community 13.0 and Odoo Enterprise 13.0 allows remote authenticated attackers to access sensitive information via crafted RPC requests, which could lead to privilege escalation.
CVE-2019-11248 1 Kubernetes 1 Kubernetes 2024-11-21 8.2 High
The debugging endpoint /debug/pprof is exposed over the unauthenticated Kubelet healthz port. The go pprof endpoint is exposed over the Kubelet's healthz port. This debugging endpoint can potentially leak sensitive information such as internal Kubelet memory addresses and configuration, or for limited denial of service. Versions prior to 1.15.0, 1.14.4, 1.13.8, and 1.12.10 are affected. The issue is of medium severity, but not exposed by the default configuration.
CVE-2019-11247 2 Kubernetes, Redhat 3 Kubernetes, Openshift, Openshift Container Platform 2024-11-21 8.1 High
The Kubernetes kube-apiserver mistakenly allows access to a cluster-scoped custom resource if the request is made as if the resource were namespaced. Authorizations for the resource accessed in this manner are enforced using roles and role bindings within the namespace, meaning that a user with access only to a resource in one namespace could create, view update or delete the cluster-scoped resource (according to their namespace role privileges). Kubernetes affected versions include versions prior to 1.13.9, versions prior to 1.14.5, versions prior to 1.15.2, and versions 1.7, 1.8, 1.9, 1.10, 1.11, 1.12.
CVE-2019-11068 8 Canonical, Debian, Fedoraproject and 5 more 23 Ubuntu Linux, Debian Linux, Fedora and 20 more 2024-11-21 9.8 Critical
libxslt through 1.1.33 allows bypass of a protection mechanism because callers of xsltCheckRead and xsltCheckWrite permit access even upon receiving a -1 error code. xsltCheckRead can return -1 for a crafted URL that is not actually invalid and is subsequently loaded.
CVE-2019-10970 1 Rockwellautomation 2 Panelview 5510, Panelview 5510 Firmware 2024-11-21 9.8 Critical
In Rockwell Automation PanelView 5510 (all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later), a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device’s file system.
CVE-2019-10962 1 Bd 2 Alaris Gateway Workstation, Alaris Gateway Workstation Firmware 2024-11-21 5.3 Medium
BD Alaris Gateway versions, 1.0.13,1.1.3 Build 10,1.1.3 MR Build 11,1.1.5, and 1.1.6, The web browser user interface on the Alaris Gateway Workstation does not prevent an attacker with knowledge of the IP address of the Alaris Gateway Workstation terminal to gain access to the status and configuration information of the device.
CVE-2019-10950 1 Fujifilm 6 Cr-ir 357 Fcr Capsula X, Cr-ir 357 Fcr Capsula X Firmware, Cr-ir 357 Fcr Carbon X and 3 more 2024-11-21 9.8 Critical
Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system.