Filtered by CWE-119
Total 13442 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2025-7914 2025-07-21 8.8 High
A vulnerability has been found in Tenda AC6 15.03.06.50 and classified as critical. Affected by this vulnerability is the function setparentcontrolinfo of the component httpd. The manipulation leads to buffer overflow. The attack can be launched remotely.
CVE-2025-7913 2025-07-21 8.8 High
A vulnerability, which was classified as critical, was found in TOTOLINK T6 4.1.5cu.748_B20211015. Affected is the function updateWifiInfo of the component MQTT Service. The manipulation of the argument serverIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7912 2025-07-21 8.8 High
A vulnerability, which was classified as critical, has been found in TOTOLINK T6 4.1.5cu.748_B20211015. This issue affects the function recvSlaveUpgstatus of the component MQTT Service. The manipulation of the argument s leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7837 2025-07-21 8.8 High
A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015 and classified as critical. Affected by this issue is the function recvSlaveStaInfo of the component MQTT Service. The manipulation of the argument dest leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7853 2025-07-21 8.8 High
A vulnerability was found in Tenda FH451 1.0.0.9. It has been rated as critical. This issue affects the function fromSetIpBind of the file /goform/SetIpBind. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7807 2025-07-21 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda FH451 1.0.0.9. This issue affects the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7806 2025-07-21 8.8 High
A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. This vulnerability affects the function fromSafeClientFilter of the file /goform/SafeClientFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7911 2025-07-21 8.8 High
A vulnerability classified as critical was found in D-Link DI-8100 1.0. This vulnerability affects the function sprintf of the file /upnp_ctrl.asp of the component jhttpd. The manipulation of the argument remove_ext_proto/remove_ext_port leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7910 2025-07-21 8.8 High
A vulnerability classified as critical has been found in D-Link DIR-513 1.10. This affects the function sprintf of the file /goform/formSetWanNonLogin of the component Boa Webserver. The manipulation of the argument curTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-7909 2025-07-21 8.8 High
A vulnerability was found in D-Link DIR-513 1.0. It has been rated as critical. Affected by this issue is the function sprintf of the file /goform/formLanSetupRouterSettings of the component Boa Webserver. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-7908 2025-07-21 8.8 High
A vulnerability was found in D-Link DI-8100 1.0. It has been declared as critical. Affected by this vulnerability is the function sprintf of the file /ddns.asp?opt=add of the component jhttpd. The manipulation of the argument mx leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7855 2025-07-19 8.8 High
A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromqossetting of the file /goform/qossetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely.
CVE-2025-7854 2025-07-19 8.8 High
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7805 2025-07-18 8.8 High
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7796 2025-07-18 8.8 High
A vulnerability, which was classified as critical, was found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7795 2025-07-18 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda FH451 1.0.0.9. Affected by this issue is the function fromP2pListFilter of the file /goform/P2pListFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7794 2025-07-18 8.8 High
A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7793 2025-07-18 8.8 High
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function formWebTypeLibrary of the file /goform/webtypelibrary. The manipulation of the argument webSiteId leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7792 2025-07-18 8.8 High
A vulnerability was found in Tenda FH451 1.0.0.9. It has been rated as critical. This issue affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7747 1 Tenda 2 Fh451, Fh451 Firmware 2025-07-18 8.8 High
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. This affects the function fromWizardHandle of the file /goform/WizardHandle of the component POST Request Handler. The manipulation of the argument PPW leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.