Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:arris:ruckus_zoneflex_r500_firmware:104.0.0.0.1347:*:*:*:*:*:*:*", "matchCriteriaId": "E93046E9-6A17-4052-8A0B-07BA0B8773F5", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:arris:ruckus_zoneflex_r500:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0EE0BD7-1B48-4AC4-A769-F12F303054FA", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "Ruckus ZoneFlex R500 104.0.0.0.1347 devices allow an authenticated attacker to execute arbitrary OS commands via the hidden /forms/nslookupHandler form, as demonstrated by the nslookuptarget=|cat${IFS} substring."}, {"lang": "es", "value": "Los dispositivos Ruckus ZoneFlex R500 versi\u00f3n 104.0.0.0.1347, permiten a un atacante autenticado ejecutar comandos arbitrarios del sistema operativo por medio del formulario oculto de /forms/nslookupHandler, como es demostrado por la subcadena nslookuptarget=|cat${IFS}."}], "id": "CVE-2020-8438", "lastModified": "2024-11-21T05:38:51.263", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2020-01-29T23:15:13.030", "references": [{"source": "cve@mitre.org", "tags": ["Exploit", "Third Party Advisory"], "url": "https://sku11army.blogspot.com/2020/01/ruckus-rce-ruckus-m500-via-injection-on.html"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Exploit", "Third Party Advisory"], "url": "https://sku11army.blogspot.com/2020/01/ruckus-rce-ruckus-m500-via-injection-on.html"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-78"}], "source": "nvd@nist.gov", "type": "Primary"}]}