Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "goform/AdvSetLanip endpoint on Tenda AC15 AC1900 15.03.05.19 devices allows remote attackers to execute arbitrary system commands via shell metacharacters in the lanIp POST parameter."}, {"lang": "es", "value": "El endpoint goform/AdvSetLanip en los dispositivos Tenda AC15 AC1900 versiones 15.03.05.19, permite a atacantes remotos ejecutar comandos arbitrarios del sistema por medio de metacaracteres de shell en el par\u00e1metro lanIp POST"}], "id": "CVE-2020-15916", "lastModified": "2024-11-21T05:06:26.530", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2020-07-23T18:15:11.763", "references": [{"source": "cve@mitre.org", "tags": ["Exploit", "Third Party Advisory"], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Exploit", "Third Party Advisory"], "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-78"}], "source": "nvd@nist.gov", "type": "Primary"}]}