Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:luvion:grand_elite_3_connect_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E09ADD9-BEF1-4065-BA45-B8A78D66D3B4", "versionEndIncluding": "2020-02-25", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:luvion:grand_elite_3_connect:-:*:*:*:*:*:*:*", "matchCriteriaId": "FF22CFEE-FD90-45B3-BC81-CA85979F3C04", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "An issue was discovered in Luvion Grand Elite 3 Connect through 2020-02-25. Authentication to the device is based on a username and password. The root credentials are the same across all devices of this model."}, {"lang": "es", "value": "Se detect\u00f3 un problema en Luvion Grand Elite 3 Connect hasta el 25-02-2020. La autenticaci\u00f3n del dispositivo es basada en un nombre de usuario y una contrase\u00f1a. Las credenciales de root son las mismas en todos los dispositivos de este modelo."}], "id": "CVE-2020-11925", "lastModified": "2024-11-21T04:58:55.160", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary"}]}, "published": "2021-04-02T16:15:13.570", "references": [{"source": "cve@mitre.org", "url": "http://seclists.org/fulldisclosure/2024/Jul/14"}, {"source": "cve@mitre.org", "tags": ["Exploit", "Third Party Advisory"], "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitor/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://seclists.org/fulldisclosure/2024/Jul/14"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Exploit", "Third Party Advisory"], "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitor/"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-522"}], "source": "nvd@nist.gov", "type": "Primary"}, {"description": [{"lang": "en", "value": "CWE-521"}], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary"}]}