Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:*", "matchCriteriaId": "1C7BB1CA-CCED-4EC9-81F4-16633561E4CF", "versionEndExcluding": "8.0.0", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0."}, {"lang": "es", "value": "Una CWE-119: Se presenta una vulnerabilidad de Errores de b\u00fafer en ProClima (todas las versiones anteriores a la versi\u00f3n 8.0.0), que permite a un atacante remoto no autenticado ejecutar c\u00f3digo arbitrario en el sistema de destino en todas las versiones de ProClima anteriores a la versi\u00f3n 8.0.0."}], "id": "CVE-2019-6824", "lastModified": "2024-11-21T04:47:13.570", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2019-07-15T21:15:10.727", "references": [{"source": "cybersecurity@se.com", "tags": ["Vendor Advisory"], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-119"}], "source": "cybersecurity@se.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-119"}], "source": "nvd@nist.gov", "type": "Primary"}]}