Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:omron:plc_cj_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7AF2C347-B4A7-4505-98A4-AFDCB1FCD386", "vulnerable": true}, {"criteria": "cpe:2.3:o:omron:plc_cs_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DF9CD76C-F6E9-4E01-A039-4049B706DD92", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "In Omron PLC CJ series, all versions, and Omron PLC CS series, all versions, an attacker could monitor traffic between the PLC and the controller and replay requests that could result in the opening and closing of industrial valves."}, {"lang": "es", "value": "En el Omron PLC CJ series, todas las versiones, y el Omron PLC CS series, todas las versiones, un atacante podr\u00eda monitorear el tr\u00e1fico entre el PLC y el controlador y reproducir las peticiones que podr\u00edan resultar en la apertura y cierre de v\u00e1lvulas industriales."}], "id": "CVE-2019-13533", "lastModified": "2024-11-21T04:25:05.593", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0"}, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:H", "version": "3.1"}, "exploitabilityScore": 2.2, "impactScore": 5.3, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2019-12-16T20:15:14.743", "references": [{"source": "ics-cert@hq.dhs.gov", "tags": ["Third Party Advisory", "US Government Resource"], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-346-02"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory", "US Government Resource"], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-346-02"}], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-294"}], "source": "ics-cert@hq.dhs.gov", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-294"}], "source": "nvd@nist.gov", "type": "Primary"}]}