Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:modbus_serial_driver:*:*:*:*:*:*:*:*", "matchCriteriaId": "D7535403-6248-47E9-A381-65680E269E6B", "versionEndIncluding": "3.17", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:x64:*", "matchCriteriaId": "82132539-3C34-4B63-BE2A-F51077D8BC5A", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:modbus_serial_driver:*:*:*:*:*:*:*:*", "matchCriteriaId": "203AD4F6-98F6-421B-8037-547FD7882228", "versionEndIncluding": "2.17", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:x86:*", "matchCriteriaId": "60366048-32FE-4081-A852-04319FD7A52C", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:driver_suite:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FE70BFB-F058-4D31-9558-B96DC0B8EFAB", "versionEndIncluding": "14.12", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "descriptions": [{"lang": "en", "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."}, {"lang": "es", "value": "Existe una vulnerabilidad de tipo referencias a recurso controlado externamente (CWE-610) en Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 y anterior, para Windows 32-bit OS:V2.17 IE 27 y anterior, y como parte del Driver Suite versi\u00f3n:V14.12 y anterior), que podr\u00eda permitir el acceso de escritura a los archivos del sistema disponibles solo para usuarios con privilegio SYSTEM u otros archivos de usuarios importantes."}], "id": "CVE-2018-7824", "lastModified": "2024-11-21T04:12:47.890", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 6.8, "confidentialityImpact": "NONE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N", "version": "2.0"}, "exploitabilityScore": 8.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N", "version": "3.1"}, "exploitabilityScore": 1.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2019-05-22T20:29:01.150", "references": [{"source": "cybersecurity@se.com", "tags": ["Patch", "Vendor Advisory"], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Patch", "Vendor Advisory"], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-610"}], "source": "cybersecurity@se.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-610"}], "source": "nvd@nist.gov", "type": "Primary"}]}