CVE-2009-3739 | 1 Rockwellautomation | 2 Ab Micrologix Controller 1100, Ab Micrologix Controller 1400 | 2025-04-11 | N/A |
Multiple unspecified vulnerabilities on the Rockwell Automation AB Micrologix 1100 and 1400 controllers allow remote attackers to obtain privileged access or cause a denial of service (halt) via unknown vectors. | ||||
CVE-2014-0755 | 1 Rockwellautomation | 2 Logix 5000 Controller, Rslogix 5000 Design And Configuration Software | 2025-04-11 | N/A |
Rockwell Automation RSLogix 5000 7 through 20.01, and 21.0, does not properly implement password protection for .ACD files (aka project files), which allows local users to obtain sensitive information or modify data via unspecified vectors. | ||||
CVE-2012-4690 | 1 Rockwellautomation | 3 Ab Micrologix Controller, Plc-5 Controller, Slc 500 Controller | 2025-04-11 | N/A |
Rockwell Automation Allen-Bradley MicroLogix controller 1100, 1200, 1400, and 1500; SLC 500 controller platform; and PLC-5 controller platform, when Static status is not enabled, allow remote attackers to cause a denial of service via messages that trigger modification of status bits. | ||||
CVE-2012-4714 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2025-04-11 | N/A |
Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value. | ||||
CVE-2012-4713 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2025-04-11 | N/A |
Integer signedness error in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a negative integer value. | ||||
CVE-2012-4715 | 1 Rockwellautomation | 1 Rslinx Enterprise | 2025-04-11 | N/A |
Buffer overflow in LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via a UDP packet with a certain integer length value that is (1) too large or (2) too small, leading to improper handling by Logger.dll. | ||||
CVE-2022-3156 | 1 Rockwellautomation | 1 Studio 5000 Logix Emulate | 2025-04-10 | 7.8 High |
A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software. | ||||
CVE-2009-0472 | 1 Rockwellautomation | 1 Controllogix 1756-enbt\/a Ethernet\/ Ip Bridge | 2025-04-09 | N/A |
Multiple cross-site scripting (XSS) vulnerabilities in the web interface in the Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge Module allow remote attackers to inject arbitrary web script or HTML via unspecified vectors. | ||||
CVE-2009-0474 | 1 Rockwellautomation | 1 Controllogix 1756-enbt\/a Ethernet\/ Ip Bridge | 2025-04-09 | N/A |
The web interface in the Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge Module allows remote attackers to obtain "internal web page information" and "internal information about the module" via unspecified vectors. NOTE: this may overlap CVE-2002-1603. | ||||
CVE-2009-0473 | 1 Rockwellautomation | 1 Controllogix 1756-enbt\/a Ethernet\/ Ip Bridge | 2025-04-09 | N/A |
Open redirect vulnerability in the web interface in the Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge Module allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. | ||||
CVE-2024-12672 | 2 Microsoft, Rockwellautomation | 2 Windows, Arena | 2025-04-03 | 7.3 High |
A third-party vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to write beyond the boundaries of allocated memory in a DOE file. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor. | ||||
CVE-2024-12175 | 1 Rockwellautomation | 1 Arena | 2025-03-13 | 7.8 High |
Another “use after free” code execution vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to craft a DOE file and force the software to use a resource that was already used. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor. | ||||
CVE-2024-11157 | 1 Rockwellautomation | 1 Arena | 2025-03-13 | 7.3 High |
A third-party vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to write beyond the boundaries of allocated memory in a DOE file. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor. | ||||
CVE-2023-2778 | 1 Rockwellautomation | 1 Factorytalk Transaction Manager | 2025-03-05 | 7.5 High |
A denial-of-service vulnerability exists in Rockwell Automation FactoryTalk Transaction Manager. This vulnerability can be exploited by sending a modified packet to port 400. If exploited, the application could potentially crash or experience a high CPU or memory usage condition, causing intermittent application functionality issues. The application would need to be restarted to recover from the DoS. | ||||
CVE-2023-2913 | 1 Rockwellautomation | 1 Thinmanager | 2025-03-05 | 7.5 High |
An executable used in Rockwell Automation ThinManager ThinServer can be configured to enable an API feature in the HTTPS Server Settings. This feature is disabled by default. When the API is enabled and handling requests, a path traversal vulnerability exists that allows a remote actor to leverage the privileges of the server’s file system and read arbitrary files stored in it. A malicious user could exploit this vulnerability by executing a path that contains manipulating variables. | ||||
CVE-2023-29463 | 1 Rockwellautomation | 1 Pavilion8 | 2025-02-27 | 8.8 High |
The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session. | ||||
CVE-2023-46290 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2025-02-27 | 8.1 High |
Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service. | ||||
CVE-2023-46289 | 1 Rockwellautomation | 1 Factorytalk View | 2025-02-27 | 7.5 High |
Rockwell Automation FactoryTalk View Site Edition insufficiently validates user input, which could potentially allow threat actors to send malicious data bringing the product offline. If exploited, the product would become unavailable and require a restart to recover resulting in a denial-of-service condition. | ||||
CVE-2023-0027 | 1 Rockwellautomation | 1 Modbus Tcp Server Add On Instructions | 2025-02-26 | 5.3 Medium |
Rockwell Automation Modbus TCP Server AOI prior to 2.04.00 is vulnerable to an unauthorized user sending a malformed message that could cause the controller to respond with a copy of the most recent response to the last valid request. If exploited, an unauthorized user could read the connected device’s Modbus TCP Server AOI information. | ||||
CVE-2023-27856 | 1 Rockwellautomation | 1 Thinmanager | 2025-02-25 | 7.5 High |
In affected versions, path traversal exists when processing a message of type 8 in Rockwell Automation's ThinManager ThinServer. An unauthenticated remote attacker can exploit this vulnerability to download arbitrary files on the disk drive where ThinServer.exe is installed. |