CVE-2015-3963 | 2 Schneider-electric, Windriver | 14 Sage 1210, Sage 1230, Sage 1250 and 11 more | 2025-04-12 | N/A |
Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value. | ||||
CVE-2015-7921 | 1 Schneider-electric | 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more | 2025-04-12 | 9.1 Critical |
The FTP server in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 has hardcoded credentials, which makes it easier for remote attackers to bypass authentication by leveraging knowledge of these credentials. | ||||
CVE-2016-4529 | 1 Schneider-electric | 3 M171, M172, Somachine Hvac Firmware | 2025-04-12 | 7.3 High |
An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag. | ||||
CVE-2011-4035 | 1 Schneider-electric | 3 Citecthistorian, Citectscada Reports, Vijeo Historian | 2025-04-11 | N/A |
Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | ||||
CVE-2013-2763 | 1 Schneider-electric | 24 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 21 more | 2025-04-11 | N/A |
The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny PLC control functions. | ||||
CVE-2013-3075 | 2 Mitsubishi-automation, Schneider-electric | 3 Mitsubishi Mx Component, Citectfacilities, Citectscada | 2025-04-11 | N/A |
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control. | ||||
CVE-2011-4033 | 1 Schneider-electric | 3 Citecthistorian, Citectscada Reports, Vijeo Historian | 2025-04-11 | N/A |
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors. | ||||
CVE-2013-0687 | 1 Schneider-electric | 1 Micom S1 Studio | 2025-04-11 | N/A |
The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file. | ||||
CVE-2013-2761 | 1 Schneider-electric | 1 Modicon M340 | 2025-04-11 | N/A |
The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service (module crash) via crafted FTP traffic, as demonstrated by the FileZilla FTP client. | ||||
CVE-2011-3144 | 2 Aveva, Schneider-electric | 3 Clearscada, Scx 67, Scx 68 | 2025-04-11 | N/A |
Cross-site scripting (XSS) vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | ||||
CVE-2011-4036 | 1 Schneider-electric | 3 Citecthistorian, Citectscada Reports, Vijeo Historian | 2025-04-11 | N/A |
Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors. | ||||
CVE-2013-0664 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2025-04-11 | N/A |
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests. | ||||
CVE-2011-3143 | 2 Aveva, Schneider-electric | 3 Clearscada, Scx 67, Scx 68 | 2025-04-11 | N/A |
Use-after-free vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via unspecified long strings that trigger heap memory corruption. | ||||
CVE-2013-0663 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2025-04-11 | N/A |
Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials. | ||||
CVE-2012-1990 | 1 Schneider-electric | 2 Kerweb, Kerwin | 2025-04-11 | N/A |
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric Kerweb before 3.0.1 and Kerwin before 6.0.1 allow remote attackers to inject arbitrary web script or HTML via (1) the evtvariablename parameter in an evts.xml action to kw.dll, (2) unspecified search fields, or (3) unspecified content-display fields. | ||||
CVE-2013-2796 | 1 Schneider-electric | 3 Citectscada, Powerlogic Scada, Vijeo Citect | 2025-04-11 | N/A |
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. | ||||
CVE-2011-4034 | 1 Schneider-electric | 3 Citecthistorian, Citectscada Reports, Vijeo Historian | 2025-04-11 | N/A |
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors. | ||||
CVE-2013-0658 | 1 Schneider-electric | 1 Accutech Manager | 2025-04-11 | N/A |
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request. | ||||
CVE-2013-2782 | 1 Schneider-electric | 2 Tburjr900, Tburjr900 Firmware | 2025-04-11 | N/A |
Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers' installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation. | ||||
CVE-2013-0657 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-04-11 | N/A |