Filtered by vendor Tenda
Subscriptions
Total
1385 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2025-7598 | 1 Tenda | 2 Ax1803, Ax1803 Firmware | 2025-07-16 | 8.8 High |
A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-1819 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-07-16 | 6.3 Medium |
A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7548 | 1 Tenda | 2 Fh1201, Fh1201 Firmware | 2025-07-15 | 8.8 High |
A vulnerability has been found in Tenda FH1201 1.2.0.14(408) and classified as critical. This vulnerability affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7549 | 1 Tenda | 2 Fh1201, Fh1201 Firmware | 2025-07-15 | 8.8 High |
A vulnerability was found in Tenda FH1201 1.2.0.14(408) and classified as critical. This issue affects the function frmL7ProtForm of the file /goform/L7Prot. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7550 | 1 Tenda | 2 Fh1201, Fh1201 Firmware | 2025-07-15 | 8.8 High |
A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been classified as critical. Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7551 | 1 Tenda | 2 Fh1201, Fh1201 Firmware | 2025-07-15 | 8.8 High |
A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been declared as critical. Affected by this vulnerability is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument modino/username leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7597 | 1 Tenda | 2 Ax1803, Ax1803 Firmware | 2025-07-15 | 8.8 High |
A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7463 | 1 Tenda | 2 Fh1201, Fh1201 Firmware | 2025-07-15 | 8.8 High |
A vulnerability was found in Tenda FH1201 1.2.0.14. It has been declared as critical. This vulnerability affects the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component HTTP POST Request Handler. The manipulation of the argument mit_ssid leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7465 | 1 Tenda | 2 Fh1201, Fh1201 Firmware | 2025-07-15 | 8.8 High |
A vulnerability classified as critical was found in Tenda FH1201 1.2.0.14. Affected by this vulnerability is the function fromRouteStatic of the file /goform/fromRouteStatic of the component HTTP POST Request Handler. The manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7505 | 1 Tenda | 2 Fh451, Fh451 Firmware | 2025-07-15 | 8.8 High |
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function frmL7ProtForm of the file /goform/L7Prot of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-7506 | 1 Tenda | 2 Fh451, Fh451 Firmware | 2025-07-15 | 8.8 High |
A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2024-4171 | 1 Tenda | 2 W30e, W30e Firmware | 2025-07-15 | 8.8 High |
A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2025-7468 | 1 Tenda | 2 Fh1201, Fh1201 Firmware | 2025-07-15 | 8.8 High |
A vulnerability has been found in Tenda FH1201 1.2.0.14 and classified as critical. This vulnerability affects the function fromSafeUrlFilter of the file /goform/fromSafeUrlFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2024-53621 | 1 Tenda | 1 Ac1206 | 2025-07-13 | 7.5 High |
A buffer overflow in the formSetCfm() function of Tenda AC1206 1200M 11ac US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | ||||
CVE-2025-50260 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2025-07-13 | 7.5 High |
Tenda AC6 v15.03.05.16_multi is vulnerable to Buffer Overflow in the formSetFirewallCfg function via the firewallEn parameter. | ||||
CVE-2025-50263 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2025-07-13 | 8.1 High |
Tenda AC6 v15.03.05.16_multi is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the list parameter. | ||||
CVE-2025-1897 | 1 Tenda | 1 Tx3 | 2025-07-13 | 6.5 Medium |
A vulnerability, which was classified as critical, has been found in Tenda TX3 16.03.13.11_multi. This issue affects some unknown processing of the file /goform/SetNetControlList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2024-4020 | 1 Tenda | 1 Fh1206 | 2025-07-12 | 8.8 High |
A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromAddressNat of the file /goform/addressNat. The manipulation of the argument entrys leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2025-1814 | 1 Tenda | 1 Ac6 | 2025-07-12 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda AC6 15.03.05.16. Affected by this issue is some unknown functionality of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-1853 | 1 Tenda | 1 Ac8 | 2025-07-12 | 8.8 High |
A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. |