Filtered by vendor Wago
Subscriptions
Total
118 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2021-21000 | 1 Wago | 54 750-8202, 750-8202 Firmware, 750-8203 and 51 more | 2025-08-15 | 5.3 Medium |
On WAGO PFC200 devices in different firmware versions with special crafted packets an attacker with network access to the device could cause a denial of service for the login service of the runtime. | ||||
CVE-2021-21001 | 1 Wago | 54 750-8202, 750-8202 Firmware, 750-8203 and 51 more | 2025-08-15 | 9.1 Critical |
On WAGO PFC200 devices in different firmware versions with special crafted packets an authorised attacker with network access to the device can access the file system with higher privileges. | ||||
CVE-2021-30186 | 2 Codesys, Wago | 56 Plcwinnt, Runtime Toolkit, 750-8202 and 53 more | 2025-08-15 | 7.5 High |
CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow. | ||||
CVE-2025-41672 | 1 Wago | 1 Device Sphere | 2025-07-14 | 10 Critical |
A remote unauthenticated attacker may use default certificates to generate JWT Tokens and gain full access to the tool and all connected devices. | ||||
CVE-2018-16210 | 1 Wago | 28 750-352, 750-352 Firmware, 750-362 and 25 more | 2025-06-13 | 6.1 Medium |
WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field. | ||||
CVE-2022-3281 | 1 Wago | 156 750-8100, 750-8100 Firmware, 750-8101 and 153 more | 2025-05-10 | 7.5 High |
WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter. | ||||
CVE-2020-12069 | 4 Codesys, Festo, Pilz and 1 more | 114 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 111 more | 2025-05-05 | 7.8 High |
In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device. | ||||
CVE-2021-34569 | 1 Wago | 98 750-8100, 750-8100 Firmware, 750-8101 and 95 more | 2025-05-01 | 9.8 Critical |
In WAGO I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory. | ||||
CVE-2021-34566 | 1 Wago | 98 750-8100, 750-8100 Firmware, 750-8101 and 95 more | 2025-05-01 | 9.1 Critical |
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS. | ||||
CVE-2021-34567 | 1 Wago | 98 750-8100, 750-8100 Firmware, 750-8101 and 95 more | 2025-05-01 | 8.2 High |
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read. | ||||
CVE-2021-34568 | 1 Wago | 98 750-8100, 750-8100 Firmware, 750-8101 and 95 more | 2025-05-01 | 7.5 High |
In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service. | ||||
CVE-2015-6472 | 1 Wago | 6 750-849, 750-849 Firmware, 750-881 and 3 more | 2025-04-20 | N/A |
WAGO IO 750-849 01.01.27 and 01.02.05, WAGO IO 750-881, and WAGO IO 758-870 have weak credential management. | ||||
CVE-2016-9362 | 1 Wago | 7 750-8202, 750-881, 750-xxxx Series Firmware and 4 more | 2025-04-20 | N/A |
An issue was discovered in WAGO 750-8202/PFC200 prior to FW04 (released August 2015), WAGO 750-881 prior to FW09 (released August 2016), and WAGO 0758-0874-0000-0111. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to edit and to view settings without authenticating. | ||||
CVE-2015-6473 | 1 Wago | 4 750-849, 750-849 Firmware, 758-870 and 1 more | 2025-04-20 | N/A |
WAGO IO 750-849 01.01.27 and WAGO IO 750-881 01.02.05 do not contain privilege separation. | ||||
CVE-2012-3013 | 1 Wago | 1 Wago I\/o System 758 Industrial Pc Device | 2025-04-11 | N/A |
WAGO I/O System 758 model 758-870, 758-874, 758-875, and 758-876 Industrial PC (IPC) devices have default passwords for unspecified Web Based Management accounts, which makes it easier for remote attackers to obtain administrative access via a TCP session. | ||||
CVE-2012-4879 | 1 Wago | 1 Wago I\/o System 758 Industrial Pc Device | 2025-04-11 | N/A |
The Linux Console on the WAGO I/O System 758 model 758-870, 758-874, 758-875, and 758-876 Industrial PC (IPC) devices has a default password of wago for the (1) root and (2) admin accounts, (3) a default password of user for the user account, and (4) a default password of guest for the guest account, which makes it easier for remote attackers to obtain login access via a TELNET session, a different vulnerability than CVE-2012-3013. | ||||
CVE-2022-3738 | 1 Wago | 14 Cc100, Cc100 Firmware, Edge Controller and 11 more | 2025-04-02 | 5.9 Medium |
The vulnerability allows a remote unauthenticated attacker to download a backup file, if one exists. That backup file might contain sensitive information like credentials and cryptographic material. A valid user has to create a backup after the last reboot for this attack to be successfull. | ||||
CVE-2022-3843 | 1 Wago | 2 852-111\/000-001, 852-111\/000-001 Firmware | 2025-03-18 | 9.1 Critical |
In WAGO Unmanaged Switch (852-111/000-001) in firmware version 01 an undocumented configuration interface without authorization allows an remote attacker to read system information and configure a limited set of parameters. | ||||
CVE-2022-45140 | 1 Wago | 14 751-9301, 751-9301 Firmware, 752-8303\/8000-002 and 11 more | 2025-03-10 | 9.8 Critical |
The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise. | ||||
CVE-2022-45139 | 1 Wago | 14 751-9301, 751-9301 Firmware, 752-8303\/8000-002 and 11 more | 2025-03-10 | 5.3 Medium |
A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality. |