CVE-2022-43378 | 1 Schneider-electric | 10 Netbotz 355, Netbotz 355 Firmware, Netbotz 450 and 7 more | 2025-02-05 | 6.5 Medium |
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause the user to be tricked into performing unintended actions when external address frames are not properly restricted. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior) | ||||
CVE-2023-25619 | 1 Schneider-electric | 14 Bmeh58s, Bmeh58s Firmware, Bmep58s and 11 more | 2025-02-05 | 7.5 High |
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol. | ||||
CVE-2023-25620 | 1 Schneider-electric | 16 140cpu65, 140cpu65 Firmware, Bmeh58s and 13 more | 2025-02-05 | 6.5 Medium |
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user. | ||||
CVE-2023-6408 | 1 Schneider-electric | 90 Ecostruxure Control Expert, Ecostruxure Process Expert, Modicon M340 Bmxp341000 and 87 more | 2025-01-23 | 8.1 High |
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack. | ||||
CVE-2023-2161 | 1 Schneider-electric | 1 Opc Factory Server | 2025-01-22 | 5 Medium |
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user. | ||||
CVE-2022-46680 | 1 Schneider-electric | 10 Powerlogic Ion7400, Powerlogic Ion7400 Firmware, Powerlogic Ion8650 and 7 more | 2025-01-21 | 8.8 High |
A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic. | ||||
CVE-2023-1049 | 1 Schneider-electric | 2 Ecostruxure Operator Terminal Expert, Pro-face Blue | 2025-01-02 | 7.8 High |
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI. | ||||
CVE-2023-2569 | 1 Schneider-electric | 1 Ecostruxure Foxboro Dcs Control Core Services | 2025-01-02 | 7.8 High |
A CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, elevation of privilege, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. | ||||
CVE-2023-27975 | 1 Schneider-electric | 2 Ecostruxure Control Expert, Ecostruxure Process Expert | 2024-12-11 | 7.1 High |
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation. | ||||
CVE-2023-5986 | 1 Schneider-electric | 1 Ecostruxure Power Monitoring Expert | 2024-12-02 | 8.2 High |
A CWE-601 URL Redirection to Untrusted Site vulnerability exists that could cause an openredirect vulnerability leading to a cross site scripting attack. By providing a URL-encoded input attackers can cause the software’s web application to redirect to the chosen domain after a successful login is performed. | ||||
CVE-2021-22764 | 1 Schneider-electric | 8 Powerlogic Pm5560, Powerlogic Pm5560 Firmware, Powerlogic Pm5561 and 5 more | 2024-11-24 | 5.3 Medium |
A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request. | ||||
CVE-2021-22763 | 1 Schneider-electric | 10 Powerlogic Pm5560, Powerlogic Pm5560 Firmware, Powerlogic Pm5561 and 7 more | 2024-11-24 | 9.8 Critical |
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device. | ||||
CVE-2024-6528 | 1 Schneider-electric | 10 Modicon Lmc058, Modicon Lmc058 Firmware, Modicon M241 and 7 more | 2024-11-21 | 5.4 Medium |
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload. | ||||
CVE-2024-6407 | 1 Schneider-electric | 2 Whc-5918a, Whc-5918a Firmware | 2024-11-21 | 9.8 Critical |
CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device. | ||||
CVE-2024-5681 | 1 Schneider-electric | 1 Ecostruxure Foxboro Dcs Control Core Services | 2024-11-21 | 7.8 High |
CWE-20: Improper Input Validation vulnerability exists that could cause local denial-of-service, privilege escalation, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. | ||||
CVE-2024-5680 | 1 Schneider-electric | 1 Ecostruxure Foxboro Dcs Control Core Services | 2024-11-21 | 7.1 High |
CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. | ||||
CVE-2024-5679 | 1 Schneider-electric | 1 Ecostruxure Foxboro Dcs Control Core Services | 2024-11-21 | 7.1 High |
CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, or kernel memory leak when a malicious actor with local user access crafts a script/program using an IOCTL call in the Foxboro.sys driver. | ||||
CVE-2024-5560 | 1 Schneider-electric | 7 Sage 1410, Sage 1430, Sage 1450 and 4 more | 2024-11-21 | 5.3 Medium |
CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service of the device’s web interface when an attacker sends a specially crafted HTTP request. | ||||
CVE-2024-5559 | 1 Schneider-electric | 2 Powerlogic P5, Powerlogic P5 Firmware | 2024-11-21 | 6.1 Medium |
CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could cause denial of service, device reboot, or an attacker gaining full control of the relay when a specially crafted reset token is entered into the front panel of the device. | ||||
CVE-2024-5558 | 1 Schneider-electric | 4 Spacelogic As-b, Spacelogic As-b Firmware, Spacelogic As-p and 1 more | 2024-11-21 | 6.4 Medium |
CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could cause escalation of privileges when an attacker abuses a limited admin account. |